When is an upgrade right for data centres and operator networks?
100G is still a relevant and stable foundation in many networks. But when multiple parallel 100G links are built out between the same nodes, the ports become a limitation or new AI and HPC environments change the traffic pattern, 400G can provide a simpler path to higher capacity. The crucial factor is not just the line speed. The upgrade needs to work with the platform, fibre infrastructure, power budget, cooling, and the planned migration.
Here we go through when it is reasonable to upgrade from 100G to 400G, which technical choices affect the investment and what should be verified before ordering.
Why are data centres and operator networks moving towards 400G?
400G is about more than capacity
AI and HPC clusters are changing the traffic pattern
400G is used in many modern clusters, but speed alone does not solve issues with oversubscription, buffering, load balancing, or poor cable design. Size the network according to the actual workload and also verify requirements for Ethernet or InfiniBand, breakout, FEC, and platform support.
Five signals that 100G should be evaluated against 400G
• Port density, available switch slots, or cable paths limit expansion.
• The traffic forecast shows that existing capacity will soon not handle normal peaks and planned growth.
• AI, HPC, storage, or DCI projects require more east-west capacity or larger uplinks.
• A planned platform upgrade provides a natural opportunity to introduce 400G without a separate migration.
A single signal is rarely sufficient as a basis for decision-making. However, when multiple signals coincide, it is reasonable to compare a continued 100G expansion with a gradual 400G migration.
100G or 400G - compare the entire link
|
Checkpoint |
Question before decision |
|
Capacity |
What load and growth should the link carry during its economic lifespan? |
|
Ports and architecture |
Can the platform provide the right port configuration, breakout and oversubscription without unnecessary complexity? |
|
Fibre and connectors |
Is the installed fibre compatible with the chosen standard, range, polarity and connector? |
|
Power and cooling |
Does the port meet the module's power class and can the chassis cool it in the current configuration? |
|
Operation and inventory |
How are spare parts, monitoring, testing methods and skills in the operations organisation affected? |
|
Economics |
What does the cost per bit and total cost look like compared to more 100G links? |
Which 400G transceiver fits the link?
|
Variant |
Typical usage and checkpoint |
|
400G SR8 |
Short multimode link. Check OM3/OM4, MPO-16, polarity and any breakout design. |
|
400G DR4 |
Up to 500 m over parallel singlemode in common IEEE applications. Check MPO interface and breakout to 4 × 100G DR1. |
|
400G FR4 |
Up to 2 km over singlemode and duplex LC in common IEEE applications. Four optical wavelengths are multiplexed in the fibre. |
|
400G LR4 |
Up to 10 km over singlemode and duplex LC in common IEEE applications. Verify power budget and receiver levels. |
|
400ZR/ZR+ |
Coherent optics for DCI and metro. Range and compatibility depend on standard, line system, link budget and platform. |
Designations, ranges and interfaces may vary between standards, MSA variants and vendor implementations. Always match both link ends against data sheets and platform compatibility matrix.
Do not forget FEC, breakout and interoperability
Therefore, verify part number, coding, software version, FEC, connector, wavelength, transmitter and receiver levels as well as temperature and power class before commissioning. A short compatibility test in the actual platform reduces the risk of late surprises.
Plan a phased migration from 100G to 400G
A complete overhaul is rarely necessary. Start where the capacity gain and simplification are greatest – for example in the spine layer, between core nodes or on heavily loaded DCI links. Retain 100G where capacity is sufficient and use breakout where the architecture and platform support it.
Document a clear target architecture, test environment and rollback plan. Measure link utilisation, error counters, optical levels and temperature before and after the change. This will allow you to determine if the investment provides the capacity and reliability that was the goal.
Checklist before ordering 400G optics
- Confirm platform, port type, operating system and software version.
- Determine the actual length of the link, fibre class, connector and polarity.
- Choose optical standard based on range and architecture – not just on price.
- Calculate power budget and check for any amplifiers or passive components.
- Verify FEC, breakout, interoperability and monitoring support.
- Check the module's power class, thermal requirements and the chassis's port limitations.
- Plan testing, spare parts, documentation and recovery before the change goes live.
When is the upgrade right?
400G is the right step when capacity needs, port density and overall operational economics justify the change – and when platform, fibre and operational model are ready. If 100G still provides sufficient capacity and ease of operation, there is no intrinsic value in upgrading sooner than necessary.
The best decision is therefore based on measurement data and a verified link design. Continue to compare 100G expansion with 400G based on traffic forecast, number of ports, power, cabling, compatibility and total cost.
Do you need help choosing 400G optics?
Tellus Fiber helps data centres, operators and municipal networks choose transceivers, cabling and optical components for the actual link. Verify platform, distance, fibre type, connector, desired port mode and breakout requirements. Then we can help you narrow down the right 400G solution before ordering.
FAQ
In terms of capacity, 400G corresponds to four times 100G, but the replacement depends on traffic flows, redundancy,
port support and breakout. Compare the architecture, not just the sum of the line speeds.
Sometimes. It depends on fibre class, length, connector, polarity and the chosen 400G standard. FR4 and LR4 typically use
duplex singlemode, while DR4 uses parallel singlemode and SR8 multimode with MPO interface.
Both are used for high data rates, but they are different form factors with different mechanical and thermal
properties. Start from which form factor and module profile the relevant platform supports.
Coherent optics are primarily relevant for DCI, metro and transport links where reach, DWDM and
spectral efficiency require it. Always check platform, line system and link budget.